BUREAU OF FIRE PREVENTION

                                                            Borough of Helmetta

                                                      60 Main Street P.O. Box 516

                                                            Helmetta, N.J. 08828

 

Under the Uniform Fire Code of the State of New Jersey, all persons who sell, rent or
transfer ownership of a residence ( home, townhouse, condo, apartment ) must have a
smoke detector, carbon monoxide detector, and fire extinguisher compliance test performed before the closing is executed.

 

 

 

 

 

N.J.A.C. 5:70-2.3

(a) Before any Use Group R-3 structure is sold, leased, or otherwise
made subject to a change of occupancy for residential purposes, the
owner shall obtain a certificate of smoke detector and carbon monoxide
compliance (CSDCMAC), evidencing compliance with  N.J.A.C. 5:70-4.19,
from the appropriate enforcing agency.

 

N.J.S.A. 52:27D-198.1.

The requirements for the type and placement of the extinguishers are as follows:

1) At least one portable fire extinguisher shall be installed in all one- and two-family dwellings

   (except seasonal rental units) upon change of occupancy;

2) The extinguisher shall be listed, labeled, charged, and operable;

3) The size shall be no smaller than 2A:10B:C, rated for residential use and weigh no more than

    10lbs;

4) The hangers or brackets supplied by the manufacturer must be used;

5) The extinguisher must be located within 10 feet of the kitchen;

6) The top of the extinguisher must not be more than 5 feet above the floor;

7) The extinguisher must be visible and in a readily accessible location, free from being blocked by

    furniture, storage, or other items;

8) The extinguisher must be near a room exit or travel path that provides an escape route to the

    exterior;

9) The extinguisher must be accompanied by an owner’s manual or written information regarding

    the operation, inspection, and maintenance of the extinguisher; and

10) Lastly, the extinguisher must be installed with the operating instructions clearly visible.

 

 

 

ONLINE
APPLICATION FOR
SMOKE DETECTOR
TEST

 

 

 

 

 

 

 

 

 

 

 

 

Applications must be submitted at least
seven days in advance of requested
Tuesday inspection date. Tests are conducted on Tuesday Evening

For Further questions, contact the Fire Marshal @ 732-521-4946, EXT 109